Online Measurement is the Most Reliable Practice
In the following test we seek to define the best ISO 4406
sampling methodology; using 5 analysis methods
Using recirculation equipment equipped with 2 online ISO 4406 laser
particle counters, with a 0.83 gpm pump and a beta 4>4193 filter,
the reservoir was filled in recirculation mode without filtration.
An ISO code 24/23/18 could be determined, which was ratified in
the other devices without any problem.
Conclusion: The veracity of the results was 100% reliable.
The fluid was filtered below <9<8<7, and the sample was taken through the counter. The surprise was that despite having repeated the procedure 3 times trying to clean the other equipment as much as possible, we were never able to obtain measurements below 16/14/12; 19/17/13 being the mean of the results of the first measurement procedure.